Hire a PLC programmer
Experienced PLC programmer for Siemens TIA Portal and Beckhoff TwinCAT, per project or as extra capacity in your team. From Duizel near Eindhoven we write structured, documented PLC code for new machines, line extensions and migrations, maintainable for the next fifteen years and not just to pass the FAT.
What we take on
New machine programs, extensions to running lines, and migrations from legacy platforms: S7-300/400 to TIA Portal, obsolete HMIs, unsupported SCADA. We program to IEC 61131-3 with a structure your own maintenance team can read: clear naming, modular function blocks, versioned code, and alarm handling that tells operators what actually happened. We also take over and stabilise codebases that other parties left behind.
How a PLC project runs
We start at your machine, not at a desk: process walkthrough, IO list, and a functional design specification you sign off before a line of code is written. Development runs against simulation where possible; commissioning is planned around your production windows: nights, weekends, or planned stops. Factory and site acceptance tests are documented against the agreed specification.
What you receive
- Commented, versioned source code that you own, with no lock-in
- Functional design specification and as-built documentation
- FAT/SAT protocols signed against your requirements
- Operator and maintenance-team handover training
- Optional support agreement after go-live
Frequently asked questions
Can you join our team as extra PLC capacity?
Yes. We can join your engineering team or project temporarily, on site or remotely: new PLC code, changes to existing programs, migrations from S7-300/400 to TIA Portal, or commissioning. We work to your standards and deliver documented, version-controlled code.
Which PLC platforms do you program?
Siemens (TIA Portal, S7), Beckhoff TwinCAT 3, Allen-Bradley / Rockwell, Omron, Mitsubishi, and CODESYS-based platforms. If your machine runs something more exotic, ask us, as the fundamentals carry over.
Can you modify a running production line without long stops?
Yes, that is most of our work. Changes are prepared and simulated offline, then commissioned during planned stops. Where downtime is critical, we stage rollback plans so the previous program can be restored in minutes.
Do you take over PLC code written by someone else?
Yes. We audit the existing program first, document its actual behaviour, and agree with you what to stabilise, what to refactor, and what to leave untouched.